1. Application:
This is our Economical series IGBT Rectifer 12V1000A Air Cooled 0-10V remote control. Lowest price with high qulity.
This rectifier is suitable for electrochemistry process, such as electroplating, electrolysis, anodizing, electrowinning, electrorefining etc. to provide stable DC power supply.
Remote control signal is our strong point, we could provide 0-10V/4-20mA, RS485 (MODBUS)/RS232/Profibus-DP/Profinet/CAN for you choice.
l Power requirement: AC 380V/400V/415V+-10%, three phase 5 line(A,B,C,N,G), and meet national electricity quality standard.
l Used indoors, ambient temperature: 0℃~+40℃.
l Relative humidity: ≤90% (relative to 20±50℃).
l Elevation: less than 2,000 meters.
l There shouldn’t be excessive amount of dust, explosive and corrosive gas in the air.
l The installation place should be without severe vibration, the vertical gradient shouldn’t exceed 5%.
l The seismic intensity of the installation site is less than 7 on the Richter scale.
l Saturated vapor pressure: daily average value is less than 2.2×10-3M pa, monthly average value is less than 1.8×10-3Mpa.
3. Technical data
1. AC Input | ||
1.1 | Input AC phase | Three phase 5 line(A,B,C,N,G) |
1.2 | Input line voltage(V) | 400V+-10% |
1.3 | Input Frequency(Hz) | 50Hz |
2. DC Output | ||
2.1 | Rated Output | 1000A/12V |
2.2 | Output mode and range | Constant Current, 0-100% of rated value |
Constant Voltage, 0-100% of rated value | ||
2.3 | Duty | 100% full load |
2.4 | Accuracy | <1% |
3. Electrical Features | ||
3.1 | Application | Electroplating |
3.2 | Regulation mode | IGBT PWM |
3.3 | Power Factor(Full load) | ≥0.93 |
3.4 | Cooling Method | Forced air cooling |
3.5 | IP degree | IP30, please specify if you require higher |
3.6 | Insulation Grade | B, please specify if you require higher |
3.7 | Working Mode | Continuous |
3.8 | Alarm type | Audible and visual alarm |
3.9 | Ripple | ≤10% |
3.10 | Timer function | Yes |
3.11 | Ampere hour function | Yes |
3.12 | PLC control interface and protocol | 0-10V |
3.13 | Control panel | On control box, through cable 3 meters long |
4. Mechanical configuration
The rectifier provides below protections to protect the rectifier and the system.
Protection type | Protection value | Rectifier action |
Under Voltage | Alarm, Rectifier stop | |
Over heat protection | 85℃ | Alarm Rectifier stop |
Over current protection | 1100A | Alarm Rectifier stop |
When the protection happens, alarm light turns to red color and rectifier stops running.
Protection reset:
After eliminating the fault, the protection alarm resets automatically.