Application
This is rectifier used for 5000A 12V Switch Mode Power Supply Water Cooling for Plating Electrolysis Anodizing Water treatment.
1). Power saving about 17% due to high efficiency of our IGBT rectifier, attached Excel form for your reference.
Item | Oil cooled SCR Rectifier | Water/air cooling IGBT rectifier |
Rated output power | 1000A*12V=12kW | |
Annual working hours | 6300hours/year(consider 21 hours/day, 300 days/year) | |
Assuming efficiency at rated output | 75% | 90% |
Power consumption/year | 12/0.75*6300=100,800kwh | 12/0.9*6300=84,000kwh |
Saved power in one year | 100,800-84,000=16,800kwh | |
Saved electricity bill (5 Rupee/hour) | 16,800*5=84,000 Rupees | |
Saved power percentage | 16,800/100,800= about 17% |
4). Customer feedback Plating quality by IGBT rectifier is better than SCR rectifier.
5). Compact size, IGBT rectifier only about 1/6 volume from SCR rectifier if for same DC output power:
Cooling method: Water cooling
Technical Parameters
1. AC Input | |||
1.1 | Input AC phase | Three phase | |
1.2 | Input line voltage(V) | 380V+/-10% | |
1.3 | Input Frequency(Hz) | 50Hz/60Hz | |
2. DC Output | |||
2.1 | Rated Output | 5000A/12V | |
2.2 | Output mode and range | Constant Current, 0-100% of rated value | |
Constant Voltage, 0-100% of rated value | |||
2.3 | Duty | 100% full load | |
2.4 | Accuracy | <1% | |
3. Electrical Features | |||
3.1 | Application | Electrochemistry | |
3.2 | Regulation mode | IGBT PWM | |
3.3 | Power Factor(Full load) | ≥0.93 | |
3.4 | Cooling Method | water cooling | |
3.5 | IP degree | IP30, please specify if you require higher | |
3.6 | Insulation Grade | B, please specify if you require higher | |
3.7 | Working Mode | Continuous | |
3.8 | Alarm type | Audible and visual alarm | |
3.9 | Water flow meter dry contact control | Contact closed, rectifier on Contact open, rectifier off |
The rectifier provides below protections to protect the rectifier and the system.
Protection type | Protection value | Rectifier action |
Driving protection | / | Alarm, rectifier stop immediately |
Over heat protection | 85℃ | Alarm Rectifier stop |
Over current protection | 1800A | Alarm Rectifier stop |
Touch panel display
Why Choose US?
Customer feedback